Note#102

Relief Valves

 The required relief area for two-phase flow is typically two to ten times the area for single-phase flow.

 For spring-operated relief valves, small amounts of leakage start to occur at 92–95% of the set pressure.

 A relief devices over-pressure is the pressure increase over its set pressure, usually expressed as a percentage of the set pressure. Pop-acting relief valves do not immediately open completely (to 100% lift). Sufficient over pressure is necessary to achieve full lift.

 if the vessel is protected by multiple relief devices, then one relief device must be set no higher than the MAWP but the others can be set as high as 105% of the MAWP.