The fluid flow velocities in water systems should not exceed certain limits to avoid noise and damaging wear and tear of pipes and fittings. The table below can be used as guidance to maximum velocities:

The fluid flow velocities in water systems should not exceed certain limits to avoid noise and damaging wear and tear of pipes and fittings. The table below can be used as guidance to maximum velocities:

A maximum variability factor of 25% has been established by MSS to limit the load differential which may be prescribed in a variable spring support
Travel stops are installed in all constant spring support before shipping. These must be present during any hydro testing, but must be removed during installation before normal operations
Hydrazine is used within both nuclear and conventional electrical power plant steam cycles to control concentrations of dissolved oxygen in an effort to reduce corrosion.
Holiday Detector provides accurate detection of pinholes, flaws, inclusions, thin spots and bubbles in a coating.
The standard manufacturing thicknesses for spiral wound gaskets are 3.2, 4.5 & 6.5 (measured across metallic strip not including the filler which protrudes 0.2 : 0.3 mm beyond the metal
Flange face finish identify specific roughness to ensure that this surface be compatible with the gasket and provide a high quality seal